Liquid Cooling
 

Get API key from Google and insert it to plugin properties to enable maps on your website.

流体用快速接头在液体冷却应用中至关重要。热控工程师需要无滴漏解决方案,以保持其设计的系统持续冷却。CPC 针对电子元件液体冷却应用设计的快速插拔 (QD) 接头杜绝了滴漏问题,经久耐用,可实现更安全、更可靠的冷却效果。

CPC 拥有无滴漏弹性密封件、简单的插拔功能以及各种可用材料,且其灵活设计可最大程度缓解流量限制问题,干插拔功能可将泄漏量降低到接近零,深受大功率超级计算机、数据中心乃至医疗设备领域的接头制造商的信赖

Universe Technology Ltd

華宇科技有限公司

◆Type 250 Lock-up Air Relay

Reliability for fail in place applications of control valves when air supply drops below acceptable pressure levels.

◆Type 600 Volume Booster

Utilizes a signal pressure to produce an output pressure with high flow capacity, that can be amplified. Signal to output ratio's available include 1:1, 1:2, 1:3 and 1:6.

◆Type 650 Positive Bias Relay

Signal operated regulator that provides an output pressure that is the sum of the input signal pressure plus a preset adjustable bias. Used to convert a low flow signal to the higher flow (up to 50 scfm) requirements of an operating system.

◆Type 6000 Volume Booster

The Type 6000 Volume Booster is a one-to-one signal to output relay that, when used with a positioner/actuator, is designed to increase the stroking speed of control valves. A large input signal change to the volume booster delivers high volume, fast action throttling control. An integral bypass valve provides system stability while allowing normal positioner airflow and normal valve actuation with small input changes. If the volume booster is to be used for on/off control valves, the bypass valve can be closed to optimize stroking speed. The Type 6000 is available in aluminum or 316 stainless steel construction.

◆Type 6500/6600 Large Flow Capacity Volume Boosters
The Type 6500 aluminum and Type 6600 stainless steel volume boosters are 1:1 signal to output relays that are utilized in applications that require high flow capacity. Typically they are used to increase throttling speed of large volume valve actuators. They are suitable for either diaphragm or piston actuators. A fixed deadband and adjustable bypass valve combine to allow small incremental downstream adjustment without opening the main booster valve. The bypass valve is used to adjust dynamic response to provide stable operation over a wide range of actuator sizes.

◆Super Mite 71L/71H

Automatically selects the higher or lower of two input signals.

◆Super Mite 74

Combines a Mite 70 with a precision 3-way valve.

◆Mite 85

Compact unit that supplies precise air pressure regulation for applications where space is limited. This unit allows large regulator performance in a small package.

© 2019 utlhk.com